FABRAL
Home
About Fabral
Light Gauge Agricultural / Wood Frame
Industrial / Architectural / Commercial
Architectural Panels, Concealed Fastener
Commercial and Industrial Panels, Exposed Fastener
Industrial Panels, Concealed Fastener
Wall & Soffit, Concealed Fastener
Select Series 12 & 612
Decor-Flush
LP-15 Liner Panel
Posi-Lock Soffit
Structural Members
Architectural Seminars
Residential
Technical Information
Project Gallery
Dealers and Distributors
Contact Us
FAQs
Industry Links
News
Euramax, Inc.

 
 
 

CFP 6 / CFP 12

 
Home   >   Industrial   >   Concealed Fastener   >   CFP 6 / CFP 12  

CFP 6 / CFP 12 Metal Roofing

CFP 6
CFP 6
 
CFP 12
CFP 12

Related Info
  • Concealed fasteners for maximum aesthetic value
  • 2 stiffening ribs standard
  • Perfect for walls, fascias and equipment screens
  • Panel ends can be swedged and endlapped
  • Available with factory-applied sealant to ensure a weathertight wall assembly
  • Standard lengths: 6'-45'

 

CFP6 Positive Wind Load Table (Steel)


Ga.

Spans

5'-0"

6'-0"

7'-0"

8'-0"

9'-0"

10'-0"

11'-0"

24

1

80

55

41

31

25

20

NR

24

2

87

61

44

34

27

22

NR

24

3

109

76

56

43

34

27

23

22

1

108

75

55

42

33

27

22

22

2

117

81

59

46

36

29

24

22

3

146

101

74

57

45

36

30

20

1

140

97

71

55

43

35

29

20

2

146

102

75

57

45

37

30

20

3

183

127

93

72

57

46

38

 

CFP6 Positive Wind Load Table (Aluminum)


Thk.

Spans

5'-0"

6'-0"

7'-0"

8'-0"

9'-0"

10'-0"

11'-0"

.032

1

67

47

34

26

21

NR

NR

.032

2

99

69

51

39

31

25

NR

.032

3

124

86

54

48

38

31

26

.040

1

101

70

51

39

31

25

21

.040

2

145

100

74

56

45

36

30

.040

3

181

126

92

71

56

45

37

Notes
  • The allowable loads are based on 1986 AISI and 1986 Aluminum Association specifications.
  • The allowable loads are based on stress only.
  • The allowable loads have been increased by 1/3 for wind loading.
  • CFP 6 Panels are to be used for siding only.
  • The CFP 6 panels should be used vertically only.

 

CFP 12 Positive Wind Load Table (Steel)


Ga.

Spans

4'-0"

5'-0"

6'-0"

7'-0"

8'-0"

9'-0"

10'-0"

24

1

131

84

58

43

33

26

21

24

2

94

60

42

31

23

NR

NR

24

3

117

75

52

38

29

23

NR

22

1

162

104

72

53

41

32

26

22

2

124

79

55

40

31

24

NR

22

3

155

99

69

51

49

31

25

20

1

192

123

85

63

48

38

31

20

2

151

97

67

49

38

30

24

20

3

189

121

84

62

47

37

30

 

CFP 12 Positive Wind Load Table (Aluminum)


Thk.

Spans

4'-0"

5'-0"

6'-0"

7'-0"

8'-0"

9'-0"

10'-0"

.032

1

140

90

62

46

35

28

22

.032

2

90

58

40

29

22

NR

NR

.032

3

112

72

50

37

28

2

NR

.040

1

217

139

115

71

54

43

35

.040

2

136

87

72

45

34

27

22

.040

3

171

107

90

56

43

34

27

Notes
  • The allowable loads are based on 1986 AISI and 1986 Aluminum Association specifications.
  • The allowable loads are based on stress only.
  • The allowable loads have been increased by 1/3 for wind loading.
  • CFP 12 panels are to be used for siding only.
  • The CFP 12 panels should be used for vertical only.

 
Home   >   Industrial   >   Concealed Fastener   >   CFP 6 / CFP 12